Background
: Measurement of VO2max(aerobic capacity) in one of the essential components in exercise prescriptionn for health promotion and maintencance, but direct measurement of VO2max is often not feasible in primary care settings. Therefore, many procedures for estimtion of VO2max have been developed. This study was conducted to determine the reliability and validity of submaximal cycle ergometer test in estimating aerobic capacity in young adults.
Methods : 20 make medical sutdents, mean age 23.5 years(range,22~25 years) were recruited as volunteers for this study. 5 students who had smoking history or mild anemia anemia were excluded in the analysis. submaximal cycle ergometer test was conducted 2 times over two-week period to examine the text0retest reliabilty of it. Validity was assessed by studying the relationships of VO2max estimated by submaximal cycle ergometer exercise test to VO2max measured by maximal cycle ergometer exercise test. All data were analysed by using the statistical Analysis System package.
Results : 1) differences between timel and time 2 were assessed by using paired t-test and there was no significant difference between them, and the pearson correlation between the measurements of aerobic cpacity by submaximal exercise test assessed at each visit was 0.72 and 0.82 when expressed in l/min and ml/kg/min. respectively.(P<0.01) 2) The pearson correlation between VO2max estimated by submaximal cycle ergometer test and VO2max measured by maximal ergometer test was 0.69 and 0.73 when expressed in ml/kg min and l/min, respectively.(P<0.01) 3) There was positive relationship between VO2max and muscle power, flexibilty and vertical jump and negative relationship between VO2max and sum of skin fold and lipid profile. Statistical significance was obsereved only relationships between VO2max and each of flexibility, muscle power(rt) and serum total cholesterol.
Conclusion : It is suggested that submaximal cycle ergometer test can provide a good estimate of VO2max determined by maximal ergometer test in young, well-motivated subjects. Further studies for other age groups and female subjects are also necessary.
연구배경 : 건강증진 프로그램에 있어서 체력요인에 대한 측정 및 평가는 필수적인 요소이다. 체력요인중 심폐지구력을 의미하는 유산소능력의 측정방법은 가스분석장치가 장착된 트레드밀이나 고정식자전거를 이용하여 직접측정법과 트레드밀이나 고정식자전거를 이용하여 심박수로서 최대 산소섭취량의 추정치를 구하는 간접측정법이 있다. 운동부하에 따라서는 최대법과 최대하법이 있다. 가스분석장치를 이용한 최대법이 가장 정확한 기준으로 되어 있으나 1차의료에서는 비교적 짧은 시간에, 적은 공간에서, 안전하고, 비용이 적게드는 고정식자전거를 이용한 최대하 검사법이 추전된다. 다라서 최대하 고정식자전거 검사법의 신뢰도와 정확도를 알아보고자 하였다.
방법 : 실험에 자원한 젊고 건강한 20명의 의과대학 학생을 대상으로 최대하 고정식자전거 검사를 2주 간격으로 2회 실시한 후 재검사 신뢰도를 구하고, 가스분석장치가 장착된 고정식자전거를 이용한 최대부하 검사로부터 구해진 최대 산소섭취량과 피어슨 상관계수로서 정확도를 구하였다.
결과 : 1) 최대하 고정식자전거를 이용한 최대산소섭취량의 예측치는 1차 측정시 2.52±0.29lmin(47.6±7.6ml/kg/min), 2차 측정시 2.58±0.30l/min(42.4±6.7ml/kg/min)로 paired t-text상 유의한 차이가 없어졌으며 (P>0.01), 피어슨 상관계수는 0.72(P<0.01)로 증등도 상관을 보였으나 단위체중당 최대산소섭취량으로 비교한 상관계수가 0.82(P<0.01)로 더 높았다. 2) 고정식자전거를 이용한 최대하 감사법의 예측 최대산소섭취량의 1차 측정치와 2차 측정치의 평균치(42.4±6.7ml/kg/min)와 가스분석장치가 장착된 고정식자전거를 이용한 최대부하법에 의해 구해진 최대산소섭취량(42.4±6.7ml/kg/min)과의 피어슨 상관계수는 0.69였으며 단위체중당 최대산소섭취량으로 본 상관계수가 0.73으로 더 높았다.(P<0.01)
결론 : 젊은 성인 남자의 유산소능력 측정에 대한 고정식자전거검사법이 유용하며 여성 및 다른 연령 집단에서의 연구가 더 필요할 것으로 사료된다.